Airstream Services provides a VIP program to help ensure your HVAC system and home electrical components are working to their full potential and to help prevent possible issues.  Semi-annual visits will ensure proper working condition of your homes HVAC units and will generally help the life of your system last many more years saving a lot of money. The annual home electrical evaluation will inspect your home’s electrical components to ensure they are fully operational and safe. 

Spring A/C Tune Up

The following items are inspected during this Spring visit:

  • Thermostat Control Operation and Response 
  • Outdoor Coils inspected and light level 1 coil cleaning (only as needed)
  • Filter/ Filtration System Condition (We will replace any filter that is provided by the homeowner. We do NOT stock filters nor provide filters for maintenance)
  • SuperHeat and Subcooling measurements will be verified IF testing indicates necessity 
  • Indoor Coil Visually inspected and Surface cleaned ONLY If Easily Accessible 
  • Starting Relays and Contactors.
  • Test Capacitors.
  • Check motors for proper operation/check belts if applicable.
  • Clear condensation drain lines. 
  • Clean electrical compartment of any spider webs or debris.
  • Airflow Delta T for cooling temperature drop
  • Verify ALL refrigeration service caps are in place and properly torqued before departure. Replace service caps as needed 
  • Eco-Friendly Non-Invasive System Testing procedure for the Refrigeration Circuit (NIST). Line Temperatures and Saturation Temperatures. *Gauges/Probes will be connected to the refrigeration circuit ONLY if NIST testing dictates a reason to do so.* (Technicians Discretion)
  • Indoor Blower Wheel Condition and Performance (Indoor Blower Wheel cleaning is not included with Maintenance as it is considered an issue if blower wheel is becoming impeded with dirt/debris)

Fall Furnace Tune Up

The following items are inspected during this Fall visit:

  • Thermostat Control Operation and Response 
  • Filter/ Filtration System Condition (We will replace and filter that is provided by the homeowner. We do NOT stock filters nor provide filters for maintenance)
  • Draft pressure switch operation and condition. 
  • Test Inducer fan capacitor if applicable.
  • Starting sequence of the gas/heating cycle. 
  • Indoor Coil Visually inspected and Surface cleaned ONLY If Easily Accessible
  • Airflow Delta T for heating temperature rise 
  • Inducer motor amperage and draft port/tubing condition.
  • Safety switches. 
  • Gas Manifold Valve operation and condition. 
  • Flame Sensor cleaning (DC Microamps measurement if applicable)
  • Inspection for flame interruptions, impingement and burner tract crossover.
  • Cleaning electrical/burner compartment of any spider webs or debris. 
  • Visually inspecting igniter for charring and corrosion. 
  • Check heat exchanger for any cracks or rust holes if easily accessible.
  • Check motors for proper operation/check belts if applicable
  • Indoor Blower Wheel Condition and Performance (Indoor Blower Wheel cleaning is not included with Maintenance as it is considered an issue if blower wheel is becoming impeded with dirt/debris)
  • Clean condensation drain line and collector box trap ONLY for 90+% gas furnace or higher.
  • Verify Water Safety Switch in place, operations and wiring for 90+% Furnaces ONLY 
  • Combustion Air Zone (CAZ) Testing for any presence of Carbon Monoxide present in the homes ambient air

Fall Heat Pump Tune Up

The following items are inspected during this Fall visit:

  • Thermostat Control Operation and Response 
  • Filter/ Filtration System Condition (We will replace and filter that is provided by the homeowner. We do NOT stock filters nor provide filters for maintenance)
  • Eco-Friendly Non-Invasive System Testing procedure for the Refrigeration Circuit (NIST). Line Temperatures and Saturation Temperatures. *Gauges/Probes will be connected to the refrigeration circuit ONLY if NIST testing dictates a reason to do so.* 
  • Airflow Delta T for heating temperature rise (BOTH Primary and Secondary heat isolation)
  • Outdoor Coils inspected and light level 1 cleaning (as needed)(ONLY if outdoor ambient temperature is over 40 degrees Fahrenheit)
  • Indoor Coil Visually inspected and Surface cleaned ONLY If Easily Accessible 
  • Check motors for proper operation/check belts if applicable.
  • Indoor Blower Wheel Condition and Performance (Indoor Blower Wheel cleaning is not included with Maintenance as it is considered an issue if blower wheel is becoming impeded with dirt/debris)
  • Starting Relays and Contactors.
  • Test Capacitor/s tolerances.
  • Safety Switches
  • Test Heat Pump Defrost operations both IN and OUT (Engage and Disengage)
  • Inspect secondary heat and controlling Relays or Sequencers. 
  • Clean electrical compartment of any spider webs or debris.
  • Verify ALL refrigeration service caps are in place and properly torqued before departure. Replace service caps as needed 
Hear Stories From Those We've Helped! Our Reviews
“This is a great company! They helped us in a time of need. Our heat went out and it was 23 degrees. Dan was prompt and professional.” - Dolores M.

VIP Membership - Electrical Service Benefits

Electrical Safety Inspection

Evaluation and inspection over the following Electrical Components:

  • Initial Panel Inspection- with the use of thermal imaging camera, we will check the main and sub panels for loose lugs and overheated wires, Check incoming power for proper voltage. All electrical wires and breakers inspected for issues pertaining to overheating and checked for proper sizing.
  • Receptacle Inspection- Check for polarity and proper installation. If installed outside, we will check for connection to a GFCI protected circuit and correct cover for damp locations.
  • GFCI Receptacle Inspection- Check to make sure unit trips and resets properly. Check for proper installation in all required locations.
  • Switch and Dimmers- Check for proper installation (should feel loose) and proper operation. Dimmers should dim lighting without bulbs strobing or turning off prematurely.
  • Lighting- visually inspect interior and exterior lighting for proper installation and operation.
  • Smoke/CO- visually inspect and test smoke and carbon monoxide detectors.
Middle Tennessee's Premier HVAC & Electrical Service Provider Contact Us Request Your Free Estimate

Maintenance Guarantee

Details & Exceptions

HVAC:

Maintenance: 30-Day Guarantee for maintenance performed. This does not apply for any electrical component failure or refrigerant charge related issue/s as technically these issues can occur at any point in time from surges, storms or natural age and degradation of the equipment. This also does not apply for any cleaning or maintenance related issues that were addressed or recommended for further additional service outside the normal scope of work for a standard maintenance service. Drain lines: Internally run or installed drain lines existing to the home are NOT covered under any warranty guarantee due to limited access to the full run of the drain line. We do not cut any existing drain line as part of our maintenance service. A drain line that needs to be cut or accessed indicates there is a problem that needs to be addressed and properly quoted for accurate remediation. Old fittings and sections of line that we cannot fully access or see is not our liability or responsibility. Any home damage related to existing drain line issues are not our responsibility or liability. We do not use any form of chemicals and positive pressure for drain line remediation or flushing due to liability purposes. All we can ensure, during our maintenance service, is that the drain is flushed and the circuit is flowing at an efficient rate and properly protected for water safety and damage at the time of service.

Electrical:

The Electrical maintenance service is completed using NEC and NFPA standards. Any discrepancies found will be noted on the report. Due to wiring/devices being in inaccessible areas (walls, attics, hidden behind furniture, meter bases, ect.) we cannot inspect, nor can we guarantee the integrity of the entire electrical system. This service includes inspecting wiring and devices that are readily accessible only. Smoke detectors to be checked for manufacture date and recommended for replacement if over 10 years old. If customer requests smoke detectors to be tested during the maintenance service, we will not be held responsible for malfunctioning smoke detectors before or after testing. This service provides a snapshot of the current state of the electrical system and any issues occurring at the time of the inspection only.

Ready to Get Started? Contact us using our contact form or give us a call at (615) 685-8822.

  • Please enter your first name.
  • Please enter your last name.
  • Please enter your phone number.
    This isn't a valid phone number.
  • Please enter your email address.
    This isn't a valid email address.
  • Please enter your address.
  • Please make a selection.
  • Please make a selection.
  • Please enter a message.